Conformity assessment: for almost every system you do it yourself, with no notified body
Conformity assessment is the procedure by which the provider of a high-risk system demonstrates, before placing it on the market or putting it into service, that it meets the requirements of Section 2 of Chapter III (Articles 8-15). The widespread idea that an outside body is always needed is wrong: for the Annex III systems in points 2 to 8, that is almost all of them, Article 43(2) provides for the internal control of Annex VI, which involves no notified body. The outside body comes in only for the biometrics of Annex III, point 1, under certain conditions, and for the products of Annex I according to their own legislation.
The obligations of Chapter III for the systems of Annex III apply from 2 December 2027 (Annex I: 2 August 2028), under Regulation (EU) 2026/1744, which moved the dates. That the examination is internal does not make it lighter: the provider signs a declaration by which it assumes responsibility for compliance (Art. 47(4)), and the documentation that supports it must be kept for ten years. This is not legal advice: I say what Articles 43 and 47-49 and Annexes VI and VII provide, in the consolidated text of 27 July 2026.
Which of the three routes: Article 43 as a function
Article 43 reads as a decision tree with three branches. If the system is in Annex III, points 2-8, there is only one route: internal control. If it is in point 1 (biometrics), the provider chooses between internal control and assessment with a notified body, but only on condition that it has applied the harmonised standards of Article 40 or, where applicable, the common specifications of Article 41; if they do not exist, if it has not applied them or has applied only part of them, it must follow Annex VII, that is, with a notified body. If the system is a safety component of a product in Annex I, Section A, the procedure laid down by the harmonisation legislation of that product applies, with the requirements of Section 2 inside the assessment.
The listing below expresses that tree in a function and tries it on four cases. It is a declared simplification: it does not know whether harmonised standards have been published for your field (something to verify in the Official Journal, which I have not done), nor does it handle the combinations of Annex I and Annex III that the last subparagraph of Article 43(3) resolves in favour of the product procedure. The line that decides is the condition on norme (standards) inside the branch for point 1: remove it and biometrics would end up in internal control even without standards applied, which is the outcome the text excludes.
"""Which conformity assessment procedure (Art. 43 Reg. EU 2024/1689, consolidated text 27.7.2026)?
Teaching simplification: it does not replace reading Art. 43 and Annexes VI and VII."""
def procedura(base: str, punto_iii: int = 0, norme: str = "nessuna") -> list:
"""base: 'allegato_iii' or 'allegato_i_a'. punto_iii: point of Annex III (1-8).
norme: 'tutte' | 'parziali' | 'nessuna' (harmonised standards or common specifications applied)."""
if base == "allegato_i_a":
return [
"Art. 43(3): follow the procedure laid down by the Union harmonisation legislation for the product",
"the Section 2 requirements become part of that assessment; the quality management system is assessed too (Art. 17)",
]
if base != "allegato_iii":
raise ValueError("unknown base")
if punto_iii == 1:
if norme == "tutte":
return ["Art. 43(1): the provider opts for one of",
" (a) internal control, Annex VI, no notified body",
" (b) quality management system + technical documentation with a notified body, Annex VII"]
return ["Art. 43(1), second subparagraph: Annex VII, with a notified body",
" reason: harmonised standards or common specifications absent, not applied, or applied only in part"]
if 2 <= punto_iii <= 8:
return ["Art. 43(2): internal control, Annex VI, no notified body"]
raise ValueError("point of Annex III out of range")
SEGUITO = [
"EU declaration of conformity (Art. 47): kept at the disposal of the authorities for 10 years",
"CE marking (Art. 48), digital if the system is provided digitally",
"registration in the EU database before placing on the market (Art. 49): Annex III, except point 2 (national registration)",
"new assessment on every substantial modification (Art. 43(4))",
]
if __name__ == "__main__":
casi = [
("CV screening (Annex III, point 4)", dict(base="allegato_iii", punto_iii=4)),
("Biometrics (point 1) with harmonised standards fully applied", dict(base="allegato_iii", punto_iii=1, norme="tutte")),
("Biometrics (point 1), standards not applied", dict(base="allegato_iii", punto_iii=1, norme="nessuna")),
("Safety component of a medical device (Annex I, Section A)", dict(base="allegato_i_a")),
]
for titolo, kw in casi:
print(titolo)
for riga in procedura(**kw):
print(" ", riga)
print("\nAfter the assessment:")
for riga in SEGUITO:
print(" -", riga)
# Output:
# CV screening (Annex III, point 4)
# Art. 43(2): internal control, Annex VI, no notified body
# Biometrics (point 1) with harmonised standards fully applied
# Art. 43(1): the provider opts for one of
# (a) internal control, Annex VI, no notified body
# (b) quality management system + technical documentation with a notified body, Annex VII
# Biometrics (point 1), standards not applied
# Art. 43(1), second subparagraph: Annex VII, with a notified body
# reason: harmonised standards or common specifications absent, not applied, or applied only in part
# Safety component of a medical device (Annex I, Section A)
# Art. 43(3): follow the procedure laid down by the Union harmonisation legislation for the product
# the Section 2 requirements become part of that assessment; the quality management system is assessed too (Art. 17)
#
# After the assessment:
# - EU declaration of conformity (Art. 47): kept at the disposal of the authorities for 10 years
# - CE marking (Art. 48), digital if the system is provided digitally
# - registration in the EU database before placing on the market (Art. 49): Annex III, except point 2 (national registration)
# - new assessment on every substantial modification (Art. 43(4))
The first two lines of output are the answer to the most frequent question: a CV-screening system (point 4) has no notified body, neither voluntary nor mandatory. The third case has one not by the provider's choice but because no standards were applied, so the risk for those working on biometrics is to find themselves on the heaviest branch only because the standards were not there or were not followed. The fourth refers to other legislation: if you make a medical device with an AI component, your counterpart is the procedure of Regulation (EU) 2017/745, not Annex VI.
What "internal control" means: the three points of Annex VI
Annex VI is short: three checks that the provider performs on itself. It deserves careful reading because it is the only procedure most developers will go through, and because each item corresponds to a document you will have to be able to produce.
- The provider verifies that the established quality management system (Art. 17) is in compliance with the requirements of Article 17.
- The provider examines the information in the technical documentation to assess whether the system complies with the essential requirements of Section 2.
- The provider verifies that the design and development process and the post-market monitoring (Art. 72) are consistent with the technical documentation.
The order is not accidental and not interchangeable: the second check judges compliance on the basis of the documentation, the third verifies that the documentation tells the truth about what you actually built and how you monitor it. This is the check that moves the work from the legal office to engineering: a well-written file that describes a system different from the one in production does not pass the check. The minimum content of the file is Annex IV (nine points), covered in the article on technical documentation.
When the notified body comes in: Annex VII
On the Annex VII route the provider lodges with a notified body of its choice, for the assessment of the quality management system, an application that includes its name and address, the list of systems covered by the same quality management system, the technical documentation of each, the documentation of the quality management system, a description of the procedures that keep it adequate and effective, and a written declaration that the same application has not been lodged with any other notified body. It then lodges a separate application for the assessment of the technical documentation of the system (Annex VII, points 3 and 4). Intended changes to the quality management system must be brought to the attention of the body, which decides whether a reassessment is necessary.
If the system is intended to be put into service by law enforcement, immigration or asylum authorities, or by Union institutions, the notified body is the market surveillance authority (Art. 43(1)). The Commission makes publicly available the list of notified bodies with their identification numbers and the activities for which they have been notified (Art. 35(2)); I have not verified how many have already been notified for AI, and the text fixes neither the time nor the cost of the assessment: any figure on this point that you find elsewhere has no source in the AI Act.
After the assessment: declaration, marking, registration
The procedure does not end with the outcome. Article 16 lists three subsequent steps that the provider must take before placing on the market, and each has a precise form. The EU declaration of conformity (Art. 47) is written, machine-readable, physically or electronically signed, one for each system; it contains the information of Annex V, including the name and type of the system, the name and address of the provider, a statement that it is issued under the sole responsibility of the provider, the harmonised standards used and, where involved, the name and number of the notified body; it is translated into a language that can be easily understood by the authorities of the Member States in which the system is made available; it is kept at the disposal of the authorities for ten years after placing on the market.
The CE marking (Art. 48) is affixed visibly, legibly and indelibly; for a system provided digitally it is a digital CE marking, allowed only if it can easily be accessed via the interface from which the system is accessed or via an easily accessible machine-readable code; where there is a notified body, the marking is followed by its identification number. Registration (Art. 49) takes place in the EU database of Article 71 before placing on the market: it applies to the systems of Annex III (with the exception of point 2, registered at national level) and also to systems the provider has concluded are not high-risk under Article 6(3). The information is, in general, public.
Modifications: when you start again
A new assessment is required for every substantial modification (Art. 43(4)): a change after placing on the market that is not foreseen or planned in the initial assessment and as a result of which compliance with the requirements of Section 2 is affected, or that modifies the intended purpose (Art. 3, point 23). For systems that continue to learn, changes pre-determined by the provider and described in the technical documentation (Annex IV, point 2(f)) are not substantial modifications. The text sets no percentage thresholds on retraining data: the question to ask is whether the change was foreseen in the file and whether it touches a requirement.
The operational corollary for whoever develops is to foresee in the file the updates you intend to make: a periodic retraining, described with the limits within which it varies, stays within the perimeter of the initial assessment; one that is not described risks being a substantial modification. Post-market monitoring (Art. 72) and the reporting of serious incidents (Art. 73: within 15 days, 2 for a widespread infringement or critical infrastructure, 10 in case of death) are continuing obligations that follow the assessment; the logs under the provider's control are kept for at least six months (Art. 19), the documentation for ten years (Art. 18).
Dates: a nuance not to be overlooked
Article 113 moves Sections 1, 2 and 3 of Chapter III to 2 December 2027 and 2 August 2028, but does not name Section 5 (Articles 40-49, where conformity assessment, the declaration, the marking and the registration sit). Read literally, that section falls under the general date of 2 August 2026. Because the procedures assess requirements that apply from 2027, the practical case of a system that has to pass them earlier does not arise; I have not found a provision that clarifies otherwise, so this is a point to verify on the consolidated version before fixing a deadline.
Frequently asked questions
Is a notified body always needed for a high-risk system?
No. For Annex III, points 2 to 8, the procedure is the internal control of Annex VI. The notified body is needed for the biometrics of point 1 when you have not fully applied the harmonised standards or the common specifications, or when the product legislation of Annex I requires it.
How long does the assessment take and how much does it cost?
The Regulation gives neither times nor costs, and I have not found a primary source that does. The cost depends on how ready the documentation already is and how well the quality system is documented. Ask the body for a quote if you are in the Annex VII case; for internal control the cost is your own work.
Does retraining the model require a new assessment?
Only if it is a substantial modification: not foreseen in the initial assessment and such as to affect compliance or the intended purpose. An update described in advance in the technical documentation is not. The text sets no percentages of new data that trigger the new assessment.
What you can do now
You can find, with Article 43, the procedure that applies to your system, you know what internal control verifies and what the notified body asks for when it is needed, and you know which three acts follow the assessment: declaration, marking, registration. To understand whether your system is subject to all this, start again from the article on providers and deployers; for the set of obligations, from the work list; for who supervises conformity, from the article on the authorities. For a first risk classification, see the article on the self-assessment tool.
Sources
- Regulation (EU) 2024/1689, consolidated text of 27.7.2026 - Articles 3, 6, 16, 18, 19, 35, 43, 47, 48, 49, 71, 72, 73 and 113, Annexes IV, V, VI and VII, consulted on 2026-11-13
- Regulation (EU) 2026/1744 (Digital Omnibus on AI), OJ L of 24.7.2026 - new dates of Article 113, consulted on 2026-11-13
The listing was run with Python 3.14.4, with identical output in two runs. Annex VII was read up to point 4.1 and the application of points 3.1-3.4; I did not read the surveillance by the notified body (point 5). I have not verified whether harmonised standards have been published for biometrics or how many bodies have already been notified.